宝盟霍伯纳官方授权代理商
宝盟霍伯纳官方授权代理商
联 系 人:钟彪
手 机:18201839258
腾讯Q Q :33632393
邮 箱:33632393@qq.com
... with own bearings | |||
![]() ![]() | |||
Square-wave cycles per turn: | 100 - 512 | ![]() |
Servo flange |
Max. output frequency: | 120 kHz | Solid shaft d= 6 mm | |
Logic level: | HTL (C), TTL, TTL (R) | ||
Permissible encoder temperature: | -20 °C to 70 °C | ||
Connection: | Internal connection terminals | ||
Weight: | approx. 200 g | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 54 | Ex II 3G 3D | |
OG 60 • HOG 60 Download... | |||
Square-wave cycles per turn: | max. 10,000 | ![]() |
Servo flange (OG 60) |
Max. output frequency: | 250 kHz | Solid shaft d= 6 mm (OG 60) | |
Logic level: | HTL (C), TTL, TTL (R) | Hollow shaft with clamping ring up to d= 12 mm (HOG 60) | |
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Plug connection | High resolution | |
Weight: | approx. 260 g (OG 60) approx. 250 g (HOG 60) |
||
Shock resistance (6 ms): | 3,000 m/s² | ||
Protection class: | IP 65 | Ex II 3G 3D | |
OG 70 • HOG 70 Download... | |||
Square-wave cycles per turn: | 50 - 10,000 | ![]() |
Servo flange (OG 70) |
Max. output frequency: | 250 kHz | Solid shaft d= 6 mm (OG 70) | |
Logic level: | HTL (C), TTL, TTL (R) | Hollow shaft up to d= 14 mm (HOG 70) | |
Permissible encoder temperature: | -20 °C to 85 °C | ||
Connection: | Internal connection terminals | ||
Weight: | approx. 360 g (OG 70) approx. 240 g (HOG 70) |
||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
OG 71 • HOG 71 Download... | |||
Square-wave cycles per turn: | OG 71: 100 up to 1,024 HOG 71: 64 up to 2,048 |
![]() |
Servo flange (OG 71) |
Max. output frequency: | 120 kHz | Solid shaft d= 6 mm (OG 71) | |
Logic level: | HTL (C), TTL, TTL (R) | Hollow shaft up to d= 14 mm (HOG 71) | |
Permissible encoder temperature: | -20 °C to 85 °C | ||
Connection: | Internal terminal strip | ||
Weight: | approx. 360 g (OG 71) approx. 240 g (HOG 71) |
||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
AHE 7 • AFE 7 Download... | |||
Square-wave cycles per turn: | 60 - 5,000 | ![]() |
Version US of OG 71/•HOG 71 |
Max. output frequency: | 120 kHz | 1/2" hollow shaft (AHE 7) | |
Logic level: | HTL (C), TTL, TTL (R) | 3/8" servo flange (AFE 7) | |
Permissible encoder temperature: | -30 °C to 70 °C | NPT 1/2" fitting | |
Connection: | Internal connection terminals | ||
Weight: | approx. 240 g (AHE 7) approx. 380 g (AFE 7) |
||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 56 | ||
HOG 75 • HOG 75 K Download... | |||
Square-wave cycles per turn: | 250 - 2,500 | ![]() |
Through-hole hollow shaft with clamping ring up to d= 26 mm (HOG 75) |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL | Cone shaft 1:10 (HOG 75 K) | |
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Internal connection terminals | ||
Weight: | approx. 320 g | ||
Shock resistance (6 ms): | 2,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
OG 8 • HOG 8 Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11mm (OG 8) |
Max. output frequency: | 120 kHz | Through-hole hollow shaft with clamping ring up to d= 16 mm (HOG 8) | |
Logic level: | HTL (C), TTL, TTL (R) | ||
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Internal connection terminals | ||
Weight: | approx. 700 g (OG 8) approx. 550 g (HOG 8) |
||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 54 | ||
OG 9 Download... | |||
Square-wave cycles per turn: | 1 - 1,250 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -30 °C to 100 °C | ||
Connection: | Terminal box | ||
Weight: | approx. 900 g | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 55 | Ex II 3G 3D | |
OG 90 Download... | |||
Square-wave cycles per turn: | 1,000 - 10,000 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 250 kHz | High HTL output current | |
Logic level: | HTL (C), TTL, TTL (R) | High resolution | |
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Terminal box | ||
Weight: | approx. 1.5 kg | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 55 | ||
HOG 9 • HOG 9 G Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Option: Cone shaft 1:10 | |
Permissible encoder temperature: | -30 °C to 100 °C | High HTL output current | |
Connection: | Plug connection | Bearing at each end | |
Weight: | approx. 700 g (HOG 9) | Protection against shaft currents | |
approx. 1,100g (HOG 9G) | Twin encoder HOG 9 G | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
FOG 9 Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -30 °C to 100 °C | ||
Connection: | Plug connection | ||
Weight: | approx. 860 g | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
POG 9 Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -30 °C to 100 °C | Twin encoder POG 9 G | |
Connection: | Terminal box | ||
Weight: | approx. 1.3 kg | ||
Shock resistance (1 ms): | 3,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
POG 9 G Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -30 °C to 100 °C | ||
Connection: | Terminal box | ||
Weight: | approx. 1.7 kg | ||
Shock resistance (1 ms): | 3,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
POG 90 Download... | |||
Square-wave cycles per turn: | 1,024 - 10,000 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 250 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -20 °C to 85 °C | High resolution | |
Connection: | large terminal box | ||
Weight: | approx. 1.5 kg | ||
Shock resistance (11 ms): | 1,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
HOG 10 Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
Hollow shaft with clamping element up to d= 20 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Option: Cone shaft 1:10 | |
Permissible encoder temperature: | -40 °C to 100 °C -50 °C to 100 °C (optional) |
High HTL output current | |
Connection: | Internal connection terminals or large terminal box | Protection against shaft currents | |
Weight: | approx. 1.6 kg | Twin encoder HOG 10 G | |
Shock resistance (6 ms): | 2,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
HOG 10 G Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
Hollow shaft with clamping element up to d= 20 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Option: Cone shaft 1:10 | |
Permissible encoder temperature: | -40 °C to 100 °C -50 °C to 100 °C (optional) |
High HTL output current | |
Connection: | Large terminal box | Protection against shaft currents | |
Weight: | approx. 2.2 kg | ||
Shock resistance (6 ms): | 2,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
HOG 100 Download... | |||
Square-wave cycles per turn: | 1,024 - 10,000 | ![]() |
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: | 250 kHz | ||
Logic level: | HTL, TTL | Option: Cone shaft 1:10 | |
Permissible encoder temperature: | -30 °C to 85 °C | High HTL output current | |
Connection: | Internal connection terminals or large terminal box | High resolution | |
Weight: | approx. 1.5 kg | Protection against shaft currents | |
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
POG 10 Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -40 °C to 100 °C -50 °C to 100 °C (optional) |
Protection against inductive shaft currents with isolated coupling (e. g. K 35) | |
Connection: | Large terminal box | ||
Weight: | approx. 1.6 kg | Twin encoder POG 10 G | |
Shock resistance (6 ms): | 2,000 m/s² | ||
Protection class: | IP 66 | ||
Ex II 3G 3D | |||
POG 10 G Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | High HTL output current | |
Logic level: | HTL, TTL, TTL (R) | Bearing at each end | |
Permissible encoder temperature: | -40 °C to 100 °C -50 °C to 100 °C (optional) |
Protection against inductive shaft currents with isolated coupling (e. g. K 35) | |
Connection: | Large terminal box | ||
Weight: | approx. 2.4 kg | ||
Shock resistance (6 ms): | 2,000 m/s² | ||
Protection class: | IP 66 | ||
Ex II 3G 3D | |||
HOG 11 (Offshore) Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: | 120 kHz | Option: Cone shaft 1:10 | |
Logic level: | HTL, TTL, TTL (R) | Protection against inductive shaft currents | |
Permissible encoder temperature: | -30 °C to 100 °C | Special corrosion protection e.g. for offshore | |
Connection: | Large terminal box | Option: Hybrid bearing | |
Weight: | approx. 1.6 kg | Option: Earthing brush for capacitive shaft currents | |
Shock resistance (6 ms): | 2,500 m/s² | Option: Heating for use down to -55°C | |
Twin encoder HOG 11 G | |||
Protection class: | IP 67 | Ex II 3G 3D | |
HOG 11 G (Offshore) Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: | 120 kHz | Option: Cone shaft 1:10 | |
Logic level: | HTL, TTL, TTL (R) | Protection against inductive shaft currents | |
Permissible encoder temperature: | -30 °C to 100 °C | Special corrosion protection e.g. for offshore | |
Connection: | Large terminal box | Option: Hybrid bearing | |
Weight: | approx. 2.2 kg | Option: Earthing brush for capacitive shaft currents | |
Option: Heating for use down to -55°C | |||
Shock resistance (6 ms): | 2,500 m/s² | ||
Protection class: | IP 67 | Ex II 3G 3D | |
POG 11 (Offshore) Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | Protection against inductive shaft currents with isolated coupling (e. g. K 35) | |
Logic level: | HTL, TTL, TTL (R) | ||
Permissible encoder temperature: | -30 °C to 100 °C | Special corrosion protection e.g. for offshore | |
Connection: | Large terminal box | Option: Hybrid bearing | |
Weight: | approx. 1.8 kg | Option: Heating for use down to -55°C | |
Shock resistance (6 ms): | 3,000 m/s² | Twin encoder POG 11 G | |
Protection class: | IP 67 | Ex II 3G 3D | |
POG 11 G (Offshore) Download... | |||
Square-wave cycles per turn: | 1 - 2,500 | ![]() |
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: | 120 kHz | Protection against inductive shaft currents with isolated coupling (e. g. K 35) | |
Logic level: | HTL, TTL, TTL (R) | ||
Permissible encoder temperature: | -30 °C to 100 °C | Special corrosion protection e.g. for offshore | |
Connection: | Large terminal box | Option: Hybrid bearing | |
Weight: | approx. 2.4 kg | Option: Heating for use down to -55°C | |
Shock resistance (6 ms): | 3,000 m/s² | ||
Protection class: | IP 67 | Ex II 3G 3D | |
HOG 12 Download... | |||
Square-wave cycles per turn: | 600, 1,024 | ![]() |
Through-hole hollow shaft with clamping ring up to d= 45 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL (C), TTL, TTL (R) | ||
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Cable connection | ||
Weight: | approx. 1 kg | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 54 | ||
HOG 131 (Offshore) Download... | |||
Square-wave cycles per turn: | 1,024 - 3,072 | ![]() |
Through-hole hollow shaft with clamping ring up to d= 36 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | ||
Permissible encoder temperature: | -40 °C to 100 °C | ||
Connection: | Large terminal box | ||
Weight: | approx. 4 kg | ||
Shock resistance (6 ms): | 2,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
EGZ 14 • AG 14 Download... | |||
Square-wave cycles per turn: | 250 - 2,500 | ![]() |
Through-hole hollow shaft up to d= 70 mm |
Max. output frequency: | 120 kHz | Especially for lift drives | |
Logic level: | HTL (C), TTL, TTL (R) | ||
Permissible encoder temperature: | -30 °C to 70 °C | ||
Connection: | Plug connection (EGZ 14) Terminal box or plug connection (AG 14) |
||
Weight: | approx. 1.2 kg | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 20, IP 54 | ||
HOG 16 Download... | |||
Square-wave cycles per turn: | 250 - 2,500 | ![]() |
Through-hole hollow shaft with clamping element up to d= 38 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | High HTL output current | |
Permissible encoder temperature: | -20 °C to 100 °C | Slip-ring earthing contact | |
Connection: | Terminal box | Option: Redundant scanning | |
Weight: | approx. 4 kg | ||
Shock resistance (6 ms): | 3,000 m/s² | ||
Protection class: | IP 66 | Ex II 3G 3D | |
HOG 161 Download... | |||
Square-wave cycles per turn: | 250 - 2,048 | ![]() |
Through-hole hollow shaft with clamping ring up to d= 75 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Option: Redundant scanning | |
Permissible encoder temperature: | -20 °C to 85 °C | ||
Connection: | Terminal box | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 54 | ||
Ex II 3G 3D | |||
HOG 163 (Offshore) Download... | |||
Square-wave cycles per turn: | 250 - 5,000 | ![]() |
Through-hole hollow shaft with clamping ring up to d= 75 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Insulated bearings | |
Permissible encoder temperature: | -30 °C to 85 °C | Special corrosion protection | |
Connection: | Large terminal box | Option: Redundant scanning | |
Weight: | approx. 3.5 kg | ||
Shock resistance (6 ms): | 1,000 m/s² | ||
Protection class: | IP 56 | Ex II 3G 3D | |
HOG 165 (Offshore) Download... | |||
Square-wave cycles per turn: | 250 - 5,000 | ![]() |
Hollow shaft with clamping element up to d= 38 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Special corrosion protection | |
Permissible encoder temperature: | -30 °C to 100 °C | Option: Protection against shaft currents | |
Connection: | Large terminal box | Option: Slip-ring earthing contact | |
Weight: | approx. 4 kg | Option: Redundant scanning | |
Shock resistance (6 ms): | 3,000 m/s² | ||
Protection class: | IP 67 | Ex II 3G 3D | |
HOG 22 • HOG 220 Download... | |||
Square-wave cycles per turn: | HOG 22: (720 - 4,000) HOG 220: (1,024) |
![]() |
Through-hole hollow shaft with clamping ring up to d= 115 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HOG 22: HTL (C), TTL, TTL (R) HOG 220: HTL, TTL, TTL (R) |
||
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Terminal box or plug connection | ||
Weight: | approx. 8.8 kg | ||
Shock resistance (6 ms): | 2,000 m/s² | HOG 28 Download... | |
Square-wave cycles per turn: | 1,024 - 2,048 | ![]() |
Through-hole hollow shaft up to d= 150 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL (C), TTL, TTL (R) | ||
Permissible encoder temperature: | -30 °C to 85 °C | ||
Connection: | Plug connection | ||
Weight: | approx. 20 kg | ||
Shock resistance (6 ms): | 2,000 m/s² | HML 131 M Download... | |
Square-wave cycles per turn: | 128 - 2,048 | ![]() |
Hollow shaft up to d= 36 mm |
Max. output frequency: | 200 kHz | Operable under oil | |
Logic level: | HTL (C), TTL, TTL (R) | ||
Permissible encoder temperature: | -20 °C to 90 °C | Magnetic sensing | |
Connection: | Special connector | Redundant sensing | |
Weight: | approx. 2.2 kg | ... without own bearings | |
HG 6 Download... | |||
Square-wave cycles per turn: | 100 - 512 | ![]() |
Servo flange |
Max. output frequency: | 120 kHz | Hollow shaft up to d= 16 mm | |
Logic level: | HTL (C), TTL, TTL (R) | Rugged construction without own bearings for very high speeds | |
Permissible encoder temperature: | -20 °C to 85°C | ||
Connection: | Internal connection terminals | Incremental disk protected in axial and radial direction HG 16 Download... | |
Square-wave cycles per turn: | 250 - 2,500 | ![]() |
Through-hole hollow shaft with clamping ring up to d= 45 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL, TTL, TTL (R) | Axial displacement max. - 0.5 mm, 1.5 mm Option: up to 2.5 mm |
|
Permissible encoder temperature: | -30 °C to 100°C | ||
Connection: | Terminal box, Option: Plug connection | Option: Redundant scanning | |
Weight: | approx. 2.4 kg | ||
Shock resistance (6 ms): | 1,000 m/s² | HG 18 • HG 22 Download... | |
Square-wave cycles per turn: | HG 18: 250 - 2,500 HG 22: 720 - 4,000 |
![]() |
Through-hole hollow shaft with clamping ring up to d= 110 mm |
Max. output frequency: | 120 kHz | ||
Logic level: | HTL (C), TTL, TTL (R) | Axial displacement max. - 0.5 mm, 1.5 mm Option: up to 2.5 mm |
|
Permissible encoder temperature: | -30 °C to 70°C | ||
Connection: | Terminal box, Option: Plug connection | Option: Redundant scanning | |
Weight: | HG 18: approx. 4.2 kg HG 22: approx. 5.8 kg |
||
Shock resistance (6 ms): | 1,000 m/s² | HG 21 • HG 211 Download... | |
Square-wave cycles per turn: | 2,500 | ![]() |
Through-hole hollow shaft up to d= 95 mm |
Max. output frequency: | 120 kHz Option: 160 kHz | ||
Logic level: | HTL (C), TTL, TTL (R) | Axial displacement max. - 0.5 mm, 1.5 mm Option: up to 2.5 mm |
|
Permissible encoder temperature: | -30 °C to 70 °C | ||
Connection: | Connector | Option: redundant scanning | |
Weight: | approx. 5.8 kg | ||
Shock resistance (6 ms): | 1,000 m/s² | HMC 16 (M) HEAG 158 V (M) Download... | |
Square-wave cycles per turn: | 128 - 8,192 | ![]() |
Hollow shaft up to d= 55 mm |
Max. output frequency: | 2,000 kHz | Magnetic sensing | |
Logic level: | HTL, TTL | ||
Permissible encoder temperature: | -30 °C / 0 °C to 70 °C / 105 °C | Redundant sensing (optional) | |
Connection: | 12 pin mating connector (male contacts) | ||
Weight: | approx. 2.4 kg | ||
Shock resistance (12 ms): | 3,000 m/s² | ||
Protection class: | HMC 16 (M) - IP 68 HEAG 158 V (M) - IP 65 |
||